Products

FATECH Electronic LTD. surge protectors for signal system are used for protection of information technology systems, and radio frequency systems, we also call signal surge protectors, or coaxial surge protectors. Signal surge protectors have two types, one is with pluggable module, and functional design for DIN rail, another one is regular signal surge protectors, which can give your computer network, telecommunication lines, cable lines and control lines reliable surge protection.
Coding system of signal surge protector:
Compact intelligent surge protection device
Combined surge protective device and monitoring module in one unit, which can monitor SPD working status, MCB working status, and count lightning times.
surge protective device monitoring module
Monitoring module,can recording lightning/surge event times, monitoring SPD working status, and/or the front breaker working status.
Class I 50kA Spark Gap Surge Arrester with Remote and Indicator
Spark gap based. Class B / Type 1, Iimp=50kA (10/350us), Uc=150V, 255V, 275V, 320V, 385V, protection mode: L-PE, N-PE / L-N, N-PE. With indication window, with remote control contacts.
1 phase 50kA lightning arrester
1 phase, Spark gap based. Class B / Type 1, Iimp=50kA (10/350us), Uc=150V, 255V, 275V, 320V, 385V, protection mode: L-PE, N-PE. With indication window, with remote control contacts.
3 poles 50kA Type 1 lightning arrester
3 poles, Spark gap based. Class B / Type 1, Iimp=50kA (10/350us), Uc=150V, 255V, 275V, 320V, 385V, protection mode: L1,L2,L3-PE. With indication window, with remote control contacts.
Type 1 50kA 3 phase lightning arrester
3 phase, Spark gap based. Class B / Type 1, Iimp=50kA (10/350us), Uc=150V, 255V, 275V, 320V, 385V, protection mode: L1,L2,L3-PE, N-PE. With indication window, with remote control contacts.
Iimp 25kA Class B spark gap surge arrester
1 pole,Spark gap based. Class I / B / Type 1, Iimp=25kA (10/350us), Uc=150V, 255V, 275V, 320V, 385V, With indication window, with remote control contacts.
1 phase type 1 25kA surge arrester
2 poles 1 phase,Spark gap based. Class I / B / Type 1, Iimp=25kA (10/350us), Uc=150V, 255V, 275V, 320V, 385V, With indication window, with remote control contacts.
3 poles Iimp 25kA Class B spark gap surge arrestor
3 poles, Spark gap based. Class I / B / Type 1, Iimp=25kA (10/350us), Uc=150V, 255V, 275V, 320V, 385V, With indication window, with remote control contacts.
Three phase Iimp 25kA type 1 spark gap surge arrester
4 poles 3 phase, Spark gap based. Class I / B / Type 1, Iimp=25kA (10/350us), Uc=150,255,275,320,385V~, 1 pole, With indication window, with remote control contacts.